Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Control Release ; 217: 300-7, 2015 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-26385166

RESUMO

A clinical study was conducted to validate the in vivo drug release performance of IntelliCap® CR capsules. 12 healthy, male volunteers were administered IntelliCap® CR capsules, filled with metoprolol as a BCS 1 model drug, and programmed to release the drug with 3 different release profiles (2 linear profiles extending over 6h and 14h, respectively, and a pulsed profile with two equal pulses separated by 5h) using a cross-over design. An oral metoprolol solution was included as a reference. Standard bioavailability variables were determined. In vivo drug release-time profiles for the IntelliCap® CR capsules were calculated from the plasma drug concentrations by deconvolution, and they were subsequently compared with the in vitro drug release profiles including assessment of level A in vitro/in vivo correlation (IVIVC). The relative bioavailability for the linear, extended release profiles was about 85% which is similar to other extended release administrations of metoprolol. There was an excellent agreement between the predetermined release profiles and the in vivo release for these two administrations. For IntelliCap® CR capsules programmed to deliver 2 distinct and equal drug pulses, the first pulse was delivered as expected whereas only about half of the second dose was released. Thus, it is concluded that the IntelliCap® system is well suited for the fast and reliable generation of in vivo pharmacokinetic data for extended release drug profiles, e.g. in context of regional drug absorption investigations. For immediate release pulses delivered in the distal GI tract this version of the device appears however less suitable.


Assuntos
Sistemas de Liberação de Medicamentos , Trato Gastrointestinal/metabolismo , Metoprolol/administração & dosagem , Administração Oral , Adolescente , Adulto , Disponibilidade Biológica , Cápsulas , Estudos Cross-Over , Liberação Controlada de Fármacos , Trânsito Gastrointestinal , Humanos , Masculino , Metoprolol/sangue , Metoprolol/química , Metoprolol/farmacocinética , Pessoa de Meia-Idade , Adulto Jovem
2.
PLoS One ; 10(7): e0129076, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26177019

RESUMO

INTRODUCTION: ColoPulse tablets are an innovative development in the field of oral dosage forms characterized by a distal ileum and colon-specific release. Previous studies in humans showed release in the ileo-colonic region, but the relationship between gastrointestinal pH and release was not experimentally proven in vivo. This information will complete the in vivo release-profile of ColoPulse tablets. MATERIALS AND METHODS: Release from ColoPulse tablets was studied in 16 healthy volunteers using the dual label isotope strategy. To determine gastrointestinal pH profiles and transit times the IntelliCap system was used. A ColoPulse tablet containing 13C-urea and an uncoated, immediate release tablet containing 15N2-urea were taken simultaneously followed by a standardized breakfast after three hours. Five minutes after intake of the tablets the IntelliCap capsule was swallowed and pH was measured until excretion in the feces. Breath and urine samples were collected for isotope analysis. RESULTS: Full analysis could be performed in 12 subjects. Median bioavailability of 13C -urea was 82% (95% CI 74-94%, range 61-114%). The median lag time (5% release of 13C) was 5:42 h (95% CI 5:18-6:18 h, range 2:36-6:36 h,) There was no statistically significant difference between lag time based on isotope signal and colon arrival time (CAT) based on pH (median 5:42 vs 5:31 h p = 0.903). In all subjects an intestinal pH value of 7.0 was reached before release of 13C from the ColoPulse tablet occurred. DISCUSSION AND CONCLUSIONS: From the combined data from the IntelliCap system and the 13C -isotope signal it can be concluded that release from a ColoPulse tablet in vivo is not related to transit times but occurs in the ileo-colonic region after pH 7.0 is reached. This supports our earlier findings and confirms that the ColoPulse system is a promising delivery system for targeting the distal ileum and colon. TRIAL REGISTRATION: ISRCTN Registry 18301880.


Assuntos
Colo/química , Colo/metabolismo , Portadores de Fármacos/farmacocinética , Voluntários Saudáveis , Íleo/química , Íleo/metabolismo , Administração Oral , Adolescente , Adulto , Idoso , Disponibilidade Biológica , Portadores de Fármacos/administração & dosagem , Portadores de Fármacos/química , Liberação Controlada de Fármacos , Feminino , Trânsito Gastrointestinal , Humanos , Concentração de Íons de Hidrogênio , Cinética , Masculino , Pessoa de Meia-Idade , Especificidade de Órgãos , Comprimidos , Adulto Jovem
3.
J Pharm Sci ; 104(9): 2855-63, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25411065

RESUMO

Gastrointestinal (GI) pH and temperature profiles under fasted-state conditions were investigated in two studies with each 10 healthy human subjects using the IntelliCap(®) system. This telemetric drug delivery device enabled the determination of gastric emptying time, small bowel transit time, and colon arrival time by significant pH and temperature changes. The study results revealed high variability of GI pH and transit times. The gastric transit of IntelliCap(®) was characterized by high fluctuations of the pH with mean values ranging from pH 1.7 to pH 4.7. Gastric emptying was observed after 7-202 min (median: 30 min). During small bowel transit, which had a duration of 67-532 min (median: 247 min), pH values increased slightly from pH 5.9-6.3 in proximal parts to pH 7.4-7.8 in distal parts. Colonic pH conditions were characterized by values fluctuating mainly between pH 5 and pH 8. The pH profiles and transit times described in this work are highly relevant for the comprehension of drug delivery of solid oral dosage forms comprising ionizable drugs and excipients with pH-dependent solubility.


Assuntos
Temperatura Corporal/fisiologia , Cápsulas Endoscópicas , Trato Gastrointestinal/fisiologia , Adulto , Química Farmacêutica , Colo/metabolismo , Colo/fisiologia , Sistemas de Liberação de Medicamentos , Jejum/metabolismo , Feminino , Esvaziamento Gástrico , Trânsito Gastrointestinal/fisiologia , Humanos , Concentração de Íons de Hidrogênio , Intestino Delgado/metabolismo , Intestino Delgado/fisiologia , Masculino , Telemetria , Termometria/instrumentação , Adulto Jovem
4.
Gastrointest Endosc ; 78(3): 520-8, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23684148

RESUMO

BACKGROUND: We developed an ingestible electronic drug delivery and monitoring system. This system includes an electronic capsule comprising a drug reservoir, a pH and temperature sensor, a microprocessor and wireless transceiver, a stepper motor, and batteries. The location of the capsule in the gut derived from pH data can be monitored in real time. The stepper motor can be remotely actuated to expel the contents of the drug reservoir. OBJECTIVES: First human study. DESIGN: Two consecutive observational studies. SETTING: University medical center. SUBJECTS: Twenty healthy volunteers. INTERVENTIONS: Study I: Ingestion and passage of the capsule. Study II: Ingestion and passage of the capsule, loaded with (99m)technetium-pertechnetate ((99m)Tc); remotely actuated expulsion of (99m)Tc in the gut. MAIN OUTCOME MEASUREMENTS: Study I: Safety, tolerability, and functionality (wireless pH and temperature recording). Study II: Tracing of the capsule and expulsion and distribution of (99m)Tc from the drug reservoir by scintigraphy. Correlating location pH with scintigraphy. RESULTS: Study I: Ingestion and passage of the capsule was safe and well tolerated. Transmitted pH and temperature data were received by the recorder in 96.5% ± 3%. Study II: pH-determined passage of the esophagogastric, gastroduodenal, and ileocolonic junction correlated well with scintigraphy. Expulsion of (99m)Tc from the capsule was successful in 9 of 10 subjects. LIMITATIONS: Subjects with relatively low body mass index. CONCLUSIONS: This electronic drug delivery and monitoring system may be a promising tool for targeted delivery of substances to well-defined areas of the GI tract.


Assuntos
Sistemas de Liberação de Medicamentos/instrumentação , Monitorização Fisiológica/instrumentação , Adulto , Temperatura Corporal , Cápsulas/efeitos adversos , Sistemas de Liberação de Medicamentos/efeitos adversos , Equipamentos e Provisões Elétricas/efeitos adversos , Feminino , Trato Gastrointestinal/diagnóstico por imagem , Trânsito Gastrointestinal , Humanos , Concentração de Íons de Hidrogênio , Masculino , Microcomputadores , Cintilografia , Tecnécio/administração & dosagem , Telemetria , Fatores de Tempo , Tecnologia sem Fio , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...